Special Valves
V2

V2

Characteristics

ports flanges PN 16/40/64
function NC
pressure range 0-64 bar (Δp max. 30 bar)
KV value
DN 15 25 40 50 80
/h 7,5 15 36 46 200
media gaseous
flow direction A B as marked
switching time DN 15 - DN 50: 60 ms
DN 65 - DN 80: 100 ms
media temperature DN 15 - DN 50: 400 °C
DN 65 - DN 80: >300 °C
ambient temperature 50 °C direct mounted pilot valve
weight DN 15 - DN 50: 23,0 kg
DN 65 - DN 80: 130,5 kg
nominal voltage Un 24 V DC
Un 230 V 40-60 Hz AC
protection IP65
energized duty rating ED 100%

The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.

Data and Downloads

 Data Sheet V2
 General Operating Manual for Valves
 Declaration of Conformity
non-electrical Equipment Cat. 2

 Drawing V2

Special Valves

V2
LVP 06
PCB-1 10
PLB 05
IV 10-3
IV 16-3

Accessories

pilot valve pilot valve
co-ax (threaded ports)
5/2-way-pilot, electro-pneumatic, G 1/8, p = 4 - 10 bar
limit switch limit switch
Icomatic
M12x1, DC 10 - 60 V, AC 15 - 250 V, -25°C to +85°C
limit switch limit switch
Balluff
M12x1, DC 10 - 30 V, -25°C to +70°C
limit switch limit switch
Honeywell
change-over